One-pipe heating system is one of the solutions for piping inside buildings with the connection of heating devices. Such a scheme seems most simple and effective. The construction of a heating branch according to the “one pipe” option costs homeowners cheaper than other methods.
To ensure the operation of the circuit, it is necessary to carry out a preliminary calculation of a single-pipe heating system - this will help maintain the desired temperature in the house and prevent loss of pressure in the network. It is quite possible to cope with this task on your own. Doubt your strength?
We will tell you what are the features of a single-tube system device, give examples of working schemes, explain what calculations must be performed at the planning stage of the heating circuit.
The device of a one-pipe heating circuit
The hydraulic stability of the system is traditionally ensured by the optimal selection of the conditional passage of pipelines (Dsl). It is quite simple to implement a stable scheme by the method of selecting diameters, without first setting up heating systems with temperature controllers.
It is to such heating systems that the one-pipe scheme with vertical / horizontal installation of radiators and in the complete absence of shut-off and control valves on risers (branches to devices) is directly related.
A good example of installing a radiator element in a circuit organized by the principle of circulation with one pipe. In this case, metal-plastic pipelines with metal fittings are used.
Using the method of changing the pipe diameters in a single-tube ring heating circuit, it is possible to balance the pressure losses that occur quite accurately. The control of the heat carrier flows inside each individual heating device is ensured by the installation of a thermostat.
Usually, as part of the process of constructing a heating system according to a one-pipe scheme, at the first stage, nodes for binding radiators are built. At the second stage, the circulation rings are linked.
The classic circuit design, where one pipe is used for the coolant flow and the distribution of water through the heat sinks. This scheme refers to the simplest options (+)
The design of the binding unit of a single device involves the determination of pressure losses on the node. The calculation is performed taking into account the uniform distribution of the coolant flow by the temperature controller relative to the connection points in this circuit section.
In the framework of the same operation, the calculation of the leakage coefficient is performed, plus the determination of the range of flow distribution parameters in the trailing section. Already relying on the calculated range of branches, a circulation ring is built.
Linking circulation rings
In order to perform high-quality alignment of the circulation rings of a single-tube circuit, a preliminary calculation is made of possible pressure losses (∆Ро). In this case, the pressure loss on the control valve (∆Рк) is not taken into account.
Further, by the value of the coolant flow rate at the final section of the circulation ring and by the ∆Рк value (graph in the technical documentation for the device), the control valve setting value is determined.
The same indicator can be determined by the formula:
Kv = 0.316G / √∆Рк,
Where:
- Sq - setting value;
- G - coolant flow rate;
- ∆Рк - pressure loss on the control valve.
Similar calculations are performed for each individual control valve in a single pipe system.
True, the range of pressure losses on each PB is calculated by the formula:
∆Рко = ∆Ро + ∆Рк - ∆Рn,
Where:
- ∆Ро - possible pressure loss;
- ∆Рк - pressure loss on the PB;
- ∆Pn - pressure loss in the area of the n-circulation ring (excluding losses in the RS).
If, as a result of calculations, the necessary values for a single-pipe heating system as a whole have not been obtained, it is recommended to use the option of a single-pipe system, which includes automatic flow controllers.
An automatic flow regulator installed on the return line of the coolant. The device regulates the total flow rate of the coolant for the entire single-pipe circuit
Devices such as automatic regulators are mounted on the end sections of the circuit (connection points on risers, branch branches) at the points of connection to the return line.
If you technically change the configuration of the automatic controller (swap the drain valve and plug), the installation of devices is possible on the coolant supply lines.
With the help of automatic flow controllers, the circulation rings are linked. In this case, the pressure loss ∆Рс at the end sections (risers, instrument branches) is determined.
The residual pressure loss within the circulation ring is distributed between the common sections of the pipelines (∆Pmr) and the general flow regulator (∆Pp).
The value of the time setting of the general controller is selected according to the graphs presented in the technical documentation, taking into account ∆Рмр of the end sections.
Calculate the pressure loss at the end sections by the formula:
∆Рс = ∆Рп - ∆Рмр - ∆Рр,
Where:
- ∆Рр - estimated value;
- ∆Rpp - set pressure drop;
- ∆Рмр - Rrab losses in pipeline sections;
- ∆Рр - Loss of Rrab in the general RV.
The automatic regulator of the main circulation ring is set up (provided that the pressure differential is not initially set) taking into account the installation of the minimum possible value from the setting range in the technical documentation of the device.
The quality of the controllability of the flows by the automation of the general regulator is controlled by the difference in pressure loss on each individual riser regulator or instrument branch.
Application and Business Case
The absence of requirements for the temperature of the cooled coolant is the starting point for the design of single-pipe heating systems on thermostats with the installation of TR on the radiator supply lines. At the same time, it is mandatory to equip the heat point with automatic adjustment.
Thermostat installed on the line supplying the coolant to the heating radiator. For installation, metal fittings were used, which are convenient for working with polypropylene pipes
Schematic solutions, where there are no thermoregulating devices on radiator supply lines, are also used in practice. But the use of such schemes is due to slightly different microclimate priorities.
Typically, single-tube schemes, where there is no automatic control, are used for groups of rooms designed to compensate for heat losses (50% or more) due to additional devices: forced ventilation, air conditioning, electric heating.
Also, the device of one-pipe systems is found in projects where the norms allow the temperature of the coolant to exceed the boundary value of the operating range of the thermostat.
Projects of apartment buildings, where the operation of the heating system is tied to the heat consumption by means of meters, is usually built on a perimeter single-pipe scheme.
The perimeter single-tube scheme is a kind of “classic of the genre”, which is often used in the practice of municipal and private housing construction. It is considered simple and economical for different conditions (+)
The economic justification for the implementation of such a scheme is subject to the location of the main risers at different points in the structure.
The main calculation criteria are the cost of two main materials: heating pipes and fittings.
According to practical examples of the implementation of the perimeter single pipe system, an increase in the Du cross section of pipelines by two times is accompanied by an increase in the cost of purchasing pipes by 2-3 times. And the costs of fittings increase to 10 times the size, depending on what material the fittings are made of.
Settlement base for installation
Installation of a one-pipe scheme, from the point of view of the location of the working elements, is practically no different from the device of the same two-pipe systems. Trunk risers are usually located outside the living quarters.
SNiP rules recommend laying of risers inside special mines or gutters. The apartment line is traditionally built around the perimeter.
An example of placement of heating system pipelines in specially punched stubs. This variant of the device is often used in modern construction.
Laying of pipelines is carried out at a height of 70-100 mm from the upper boundary of the floor plinth. Or installation is done under a decorative plinth with a height of 100 mm or more and a width of up to 40 mm. Modern production produces such specialized linings for the installation of plumbing or electrical communications.
The radiators are strapped using a top-down scheme with pipes supplied on one side or on both sides. The location of the thermostats “on a specific side” is not critical, but if the heating appliance is installed next to the balcony door, the TP installation is necessarily performed on the side farthest from the door.
Laying pipes behind the baseboard seems predominant from a decorative point of view, but it brings to mind the shortcomings when it comes to passing areas where there are indoor doorways.
Pipelines laid under a decorative plinth. We can say that the classic solution for single-pipe systems implemented in new buildings of different classes
The connection of heating devices (radiators) with single-pipe risers is carried out according to schemes that allow slight linear elongation of pipes or according to schemes with compensation for elongation of pipes as a result of temperature changes.
The third version of the circuit solutions, where the use of a three-way controller is supposed, is not recommended for reasons of economy.
If the device of the system provides for the laying of risers hidden in the gates of the walls, it is recommended to use angle thermostats of the RTD-G type and shut-off valves like devices from the RLV series as connecting fittings.
Connection options: 1,2 - for systems allowing linear expansion of pipes; 3.4 - for systems designed for the use of additional heat sources; 5.6 - decisions on three-way valves are considered unprofitable (+)
The diameter of the pipe branch to the heating devices is calculated by the formula:
D> = 0.7√V,
Where:
- 0,7 - coefficient;
- V - the internal volume of the radiator.
The branch is performed with a certain slope (at least 5%) in the direction of the free exit of the coolant.
Selection of the main circulation ring
If the design solution involves a heating system based on several circulation rings, the choice of the main circulation ring is necessary. The choice theoretically (and practically) should be made according to the maximum heat transfer value of the most remote radiator.
This parameter to some extent affects the assessment of the hydraulic load as a whole attributable to the circulation ring.
The circulation ring in the image of the structural diagram. There may be several such rings for different design options. In this case, only one ring is the main (+)
The heat transfer of a remote device is calculated by the formula:
ATP = Qv / Qop + ΣQop,
Where:
- Atp - estimated heat transfer of the remote device;
- Qv - the necessary heat transfer of the remote device;
- Qop - heat transfer from radiators to the room;
- ΣQop - the sum of the necessary heat transfer of all devices in the system.
In this case, the parameter of the amount of necessary heat transfer may consist of the sum of the values of the devices designed to serve the whole building or only part of the building. For example, when calculating heat separately for rooms covered by one separate riser or separately taken areas serviced by the instrument branch.
In general, the calculated heat transfer of any other heating radiator installed in the system is calculated by a slightly different formula:
ATP = Qop / Qpom,
Where:
- Qop - the necessary heat transfer for a separate radiator;
- Qhom - thermal demand for a particular room where a single-tube scheme is used.
The easiest way to deal with the calculations and the application of the obtained values is on a specific example.
Practical calculation example
For a residential building requires a one-pipe system controlled by a thermostat.
The value of the nominal throughput of the device at the maximum setting border is 0.6 m3/ h / bar (k1). The maximum possible throughput characteristic for this setting value is 0.9 m3/ h / bar (k2).
The maximum possible pressure difference TP (at a noise level of 30 dB) is not more than 27 kPa (ΔP1). Pump head 25 kPa (ΔP2) The operating pressure for the heating system is 20 kPa (ΔP).
It is necessary to determine the pressure loss range for TP (ΔP1).
The value of internal heat transfer is calculated as follows: Atr = 1 - k1 / k2 (1 - 06/09) = 0.56. From here, the required range of pressure losses on the TP is calculated: ΔP1 = ΔP * Atr (20 * 0.56 ... 1) = 11.2 ... 20 kPa.
If independent calculations lead to unexpected results, it is better to contact specialists or use a computer calculator to check.
A detailed analysis of the calculations using a computer program with explanations on the installation and improvement of system functionality:
It should be noted that a full-scale calculation of even the simplest solutions is accompanied by a mass of calculated parameters. Of course, it is fair to calculate everything without exception, provided that a heating structure is organized that is close to the ideal structure. However, in reality there is nothing perfect.
Therefore, they often rely on calculations as such, as well as practical examples and the results of these examples. This approach is especially popular for private housing construction.
Is there anything to supplement, or have questions about calculating a single-pipe heating system? You can leave comments on the publication, participate in discussions and share your own experience in arranging the heating circuit. The contact form is located in the lower block.